How to Estimate the Runtime of a Battery Pack

The simplest runtime formula is: runtime (hours) = usable capacity (mAh) ÷ average current (mA). It looks easy, but the key word is "usable".
Usable capacity is less than rated capacity for three reasons. First, the cut-off voltage: when the pack reaches the protection threshold, remaining energy cannot be used. Second, discharge rate: at high current, effective capacity drops due to internal resistance. Third, temperature: below 0°C, a normal lithium cell may deliver only 70–80% of rated capacity.
Worked example: a pair of heated gloves with 2 x 3000mAh 3.7V packs (11.1Wh each), heating at 5W in total for both gloves. Average current at 3.7V is about 1350mA per pack at full power. Runtime at full power is roughly 3000 ÷ 1350 ≈ 2.2 hours; at medium setting (60% power) about 3.5–4 hours.
For products with motors or pumps, remember that starting current can be several times the running current; the PCM must be chosen so the start surge does not trigger over-current protection.
Our engineering team routinely helps customers size batteries before sampling. Send us your device's voltage range, average and peak current, and target runtime, and we will propose capacity, cell type and pack configuration with a simulation of expected runtime.